How do you fit needles onto a McCormick International B47 baler?

1 answer

Answer

1140516

2026-03-21 07:35

+ Follow

with the bale chamber empty unbolt old needles bolt on new ones but leave loose

disconnect needle drive you can then operate by hand push needles up till they ride over knotter adjust so they just clear knotter disc and brush against side so they drop the twine into the slot

minor adjustment might be needed when operated