if there are magnets on the stator
and the commutator is phased properly
this is known as a permanent magnet dc motor
the starting torque is dependent on armature current and the strength of the magnet
the speed is directly proportional to the armature voltage
a shunt motor needs the field energized for starting.
more field more starting torque