What is basic control signal used in 8085?

1 answer

Answer

1026368

2026-07-21 10:20

+ Follow

The control signals in an 8085 are already generated. They are CLK, S0, S1, ALE, RD-, WR-, IO/M-, INTA-, HLDA, SOD, and RESET OUT. The only control signal that needs to be generated in a medium to large bus organization is DATAENEABLE-. This is optional, if the external logic is compatible but, if not, it needs to be generated from ALE, S1, and CLK, in order to properly drive the data bus buffers without encountering a race condition during WR-. Basically, DATAENABLE- is equal to (RD- when ALE is low) if S1 is high, and it is equal to ALE if S1 is low.